Knowledgebase: Projetex
I have a problem when I try to connect to the Projetex Server (Port 212 is closed)
Posted by Alexey Sokolov (AIT) on 13 June 2014 10:59 AM

This issue is usually caused by two possible problems:

a) You have different Projetex builds installed on your Projetex Server and Projetex Workstation. In this case, download the latest Projetex build and install it on your server and workstation computers over the existing copies of the program, without uninstalling beforehand. You can always download the latest builds of owned products at your personal profile at http://clients.translation3000.com 

b) If you are sure that you have the same build on both computers, please make sure that:

- The Server is active and the database is in the Online state.

- Ports 212 and 47111 (or 211 and 47110 for versions of Projetex prior to Projetex 3D) must be open in the Server machine's firewall.

- Projetex.exe must be added to the trusted applications list on Server and Workstation PCs.

- fbserver.exe must be added to trusted applications list on Server PC (only for versions of Projetex prior to Projetex 3D). 

To add a program to the Windows Firewall exceptions list (Windows 7/8):

  1. Click Start and select Control Panel.
  2. Click System and Security.
  3. Click Allow a program through Windows Firewall to open the Allow programs to communicate through Windows Firewall screen.
  4. Click to check mark the box for the required application.
    NOTE: If the program is missing from the Allowed programs and features: list, click the Allow another program... button and browse to the directory for the program executable file, then click OK.
  5. Click OK to close the Allow programs to communicate through Windows Firewall screen.
(4 vote(s))
Helpful
Not helpful

Comments (0)
© AIT Translation Management Solutions, . Awesome Software Tools for Translators and Translation Agencies.
Privacy Policy | Data Processing Agreement